Product Group Image

Hydronic Underfloor Heating/Cooling

 

LOW ENERGY - INVISIBLE RADIANT HEAT

  
Underfloor heating is a clean, safe and zero-allergen central heating system. The system operates at low water temperatures reducing operating costs to a minimum. The floor slab transforms into a slow-release radiant heat bank providing uniform temperature throughout. Underfloor radiant heat systems are almost aligned with the 'optimum heat curve' as defined by the heating industry making it the most economical and efficient means of heating.

Hunt Pipe Positioning Board

product image: Hunt Pipe Positioning Board

INSULATION AND PIPE LAYOUT IN ONE

 

Panel size: 

1200mm x 800mm x 55mm

Concrete Screed:

20-50mm cover on top of pipe

Material Grade:

Flame retardant expanded polystyrene

Density:

30kg/m3

Compressive Stress: 

160kPa at 10% deformation

Cross breaking strength:

260 kPa minimum

Max. contact temperature:

70 degrees celcius

Hydronic Pipe Supported:

16mm, 18mm and 20mm OD

Panel Jointing:

10mm overlock on all sides

Cutting Tools:

Hand knife, handsaw or hot knife

Screed Thickness:

Minimum 20mm from top of pipe positioning board

 

 